Features:

  • 3-pole Fall-of-Potential earth testing for basic measurements
  • 2-pole resistance measurements for added versatility
  • Easily capture values with single-button operation
  • Ensure accurate measurements with automatic ‘noise’ voltage detection
  • Hazardous voltage warning offers increased user protection
  • Clearly read and record data with a large, backlit display
  • Rugged holster and design for tough work environments
  • Portable size allows for easy transportation
  • Instantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting
  • 600 V Cat II
  • Type  : Earth Resistance Ground Tester
  • Earth Resistance Measurement Upto :  0.15 Ω to 2 kΩ
  • Resolution :  0.01 Ω to 1 Ω
  • Dimensions (in mm) :  113 x 54 x 216 mm
  • Weight :  0.850 Kg
  • Model No :  1621
Description

Details

 General specifications
  Measuring functions
   3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage
  Intrinsic error
   Refers to the reference temperature range and is guaranteed for one year
  Measuring rate
   2 measurements/second
  Battery[1]
   One 9 volt alkaline (LR61)
  Battery condition
   LO-BAT is displayed if voltage drops below 6.5 V
  Voltages
  Between jacks H/C2 and E/C1:  250 Veff maximum (effective voltage)
  Between jacks S/P2 and E/C1:  250 Veff maximum
  Climatic class
   VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87)
  Temperature performance[2]
  Working:  -10 °C to +50 °C (+14 °F to +122 °F)
  Operating:  0 °C to +35 °C (+32 °F to +95 °F)
  Storage:  -20 °C to +60 °C (+68 °F to +140 °F)
  Reference:  +23 °C ± 2 °C (+73 °F ± 4 °F)
  Temperature coefficient
   ± 0.1 % of range per degree Kelvin
  Safety
   IEC/EN 61010-1, 600 V CAT II, pollution degree 2
  Dimensions
   113 mm x 54 mm x 216 mm (4.5 in x 2.1 in x 8.5 in), including holster
  Weight
   850 g (1.9 lb), including standard accessories, volume approximately 600 cm3
  Electrical specifications
  Maximum deviations:    E1 Influence factor Position
   E1 Deviation influence 0 %
  E2 Influence factor Supply voltage
  E2 Deviation influence 0 %
  E3 Influence factor Temperature 
  E3E3 Deviation influence 2.3 %
  E4 Influence factor Serial interference voltage (20 V)
  E4 Deviation influence 0.6 %
  E5 Influence factor Probe- and auxiliary probe resistance
  E5 Deviation influence 10 %
  Test voltage   3.7 kV
  Protection type   IP 40; IEC/EN 60529
  Electromagnetic
  compatibility
  Emission: IEC/EN 61326 Class B
  Immunity: IEC/EN 61326 Annex C
  RE resistance
  measurement
  Measuring method Current-voltage measurement with improved   cross-talk
  attenuation, no compensation of measuring lead resistance, with
  probe (3-pole) or without probe (2-pole), as per IEC/EN 61557-5
  Open circuit voltage 23 to 24 V ac
  Short circuit current > 50 mA ac
  Measuring frequency 128 Hz
  Maximum permissible overload 250 Veff
  Measuring time   8 seconds (average from when START is pressed)
  Limit input   Tester retains set value even if instrument is turned off (assuming   battery
  power supply is sufficient)
  Automatic changeover    of  Resolution   RH < 7 kΩ
  Resolution 0.01 ΩRH < 50 kΩ
  Resolution 0.1 ΩRH > 50 kΩ
  Resolution 1 Ω
  Interference voltage
  display dc + ac
  Vmax 30 Veff
  Common mode rejection > 80 dB at 50 Hz and 60 HzRi 680 kΩ
  Measuring uncertainty < 10 % for pure ac and dc signals
  Measuring range
  0.15 Ω to 20 Ω   Resolution 0.01 Ω
  Display range 0 to 19.99 Ω
  200 Ω   Resolution 0.1 Ω
  Display range 20 to 199.9 Ω
  2 kΩ   Resolution 1 Ω
  Display range 200 to 1999 Ω
  Intrinsic uncertainty   ± (6 % of measured value + 5D)
  Operating uncertainty
  IEC 61557[1]
  ± (18 % of measured value + 5D)
  Notes:   [1] Covers all deviations caused by influence quantities E1-E5.
  If the deviation E4 caused by high probe or auxiliary probe   resistance is higher
  than specified flashes.
  Measured values are outside of the specified operating uncertainty.

Earth Ground Tester 1621 includes :

  • Users manual
  • Two measuring leads with alligator clips, 2 m (6 ft)
  • One battery, 9 V alkaline (LR61)
  • One protective holster, yellow